APC NetShelter Rack PDU Advanced, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309

1 offer · 1 shop · last checked 2026-10-29 06:11 (Europe/Vienna)

PDU types
Metered
Type
Three-phase
Form factor
Rackmount
Rack capacity
0U
Product image: APC NetShelter Rack PDU Advanced, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC3091 / 8

Item price

EUR 1.747,71

Sold by Netzwerkartikel.de · APDU10250ME · New

Item price only. Check the cost details in the offers below.

Offers

1 live offer

Ordered by delivered total, lowest first. Offers whose total is not stated follow; that placement says nothing about their price.

Links to merchants are affiliate links (advertising). Tallybuy earns a commission if you buy. The offers, their order and what you pay stay the same. About affiliate links

Observed item prices

Netzwerkartikel.de, one listing

This is the item price of one seller's listing, not a delivered total and not the best price across sellers.

Observed prices over time

Latest
EUR1.747,7129 Oct 2026
Lowest
Unchanged since 28 Oct 2026
Observed prices over time
DayLowestHighestLastChecks
29 Oct 2026EUR1.747,71EUR1.747,71EUR1.747,711
28 Oct 2026EUR1.747,71EUR1.747,71EUR1.747,711

About this product

APC NetShelter Rack PDU Advanced, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309, Metered, 0U, Three-phase, Rackmount, Vertical, Black

Read the full source description

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Text from Specs Icecat.

Specifications

55 specifications

Product data: Specs Icecat

GTIN
00731304439684
MPN
APDU10250ME
Design9
PDU types
Metered
Type
Three-phase
Form factor
Rackmount
Rack capacity
0U
Mounting
Vertical
Product colour
Black
Display
LCD
On/off switch
Yes
Regulatory Approvals
CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Ports & interfaces5
AC outlets quantity
42 AC outlet(s)
Power plug
IEC 60309
AC outlet types
C13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports
2
USB ports quantity
1
Features9
Daisy chain
Yes
Reset button
Yes
LED indicators
Activity, Network, Power
Colour-coded outlets
Yes
Cable length
1.8 m
Security algorithms
128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protection
Yes
Recommended replacement
APDU11250ME
Compatible products
Compatible with most NetShelter SX enclosures and third-party racks
Management features4
Monitoring
Current, Humidity, Power, Temperature, Voltage
Outlet control
Lock-out, Recycle, Turn on
Firmware upgradeable
Yes
Firmware upgradeable via
Network, USB
Power11
Nominal input voltage
400 V
AC input frequency
50 - 60 Hz
Maximum current
16 A
Nominal output voltage
230 V
Output voltage
230 V
Load capacity
11500 VA
Number of phases
3
Maximum total current draw per phase
16 A
Power protection features
Overload
Maximum power
11040 W
Surge protection
Yes
Certificates1
Compliance certificates
RoHS
Operational conditions7
Operating temperature (T-T)
-5 - 60 °C
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Operating altitude
0 - 3048 m
Non-operating altitude
0 - 15240 m
Operating temperature (T-T)
23 - 140 °F
Weight & dimensions4
Width
56 mm
Depth
55 mm
Height
1490 mm
Weight
5.7 kg
Packaging data4
Package weight
7.7 kg
Package width
208 mm
Package depth
116 mm
Package height
1720 mm
Logistics data1
Total carbon footprint (kg of CO2e)
8717.32